About Clinical Chemistry, the determinations of blood constituents like glucose, uric acid, triglycerides, cholesterol, blood gas, enzymology, electrolytes, drugs and the clinical significance of their abnormal values. Deals also with quality assurance and function tests.
AdSense
Tuesday, April 15, 2008
LABORATORY MATHEMATICS
1. Percent solutions - W/V (Weight over volume), W/W (weight over weight), V/V(volume over volume)
2. Normality - the gram equivalent weight of a solute per liter of solution.
3. Molarity - the gram molecular weight of a solute per lier of solution.
4. Molality - the gram molecular weight of solute per 1,000 gram of solvent.
Thursday, April 3, 2008
THYROID FUNCTION TESTS
These are laboratory tests that are performed to determine thyroid function.
PRECAUTIONS IN SPECIMEN COLLECTION & HANDLING
•RED TOP OR YELLOW TOP CAN BE USED
•AVOID USE OF LIPEMIC & HEMOLYZED SERUM
•NEWBORNS- FILTER PAPER BLOT CAN BE USED
•FASTING- NOT NEEDED
•SAMPLES CAN BE REFRIGERATED-24 HRS.
•FROZEN FOR 30 DAYS (AVOID REPEATED THAWING)
BLOOD TESTS:
•Thyroid-Stimulating Hormone (TSH)
This is a significant marker for hypothyroidism. an increase in its concentration indicates hypothyroidism and a decrease indicates hyperthyroidism
Thyroxine (T4) and Triiodothyronine (T3)
increased concentrations indicate hyperthyroidism
decreased concentrations indicate hypothroidism
•Thyroxine-Binding Globulin. (TBG)
this is the major binding protein of thyroid hormones
Other tests:
rT3, T3U, FTI, FT3, FT4
Stimulation Tests
•-TRH STIMULATION TEST
TRH IS INJECTED INTO THE PATIENT AND THE RESPONSE OF THE PITUITARY GLAND IS OBSERVED.
•TSH STIMULATION TEST
TSH IS GIVEN TO THE PATIENT AND THEN THE REPONSE OF THE THYROID GLAND IS MEASURED.
THE CATECHOLAMINES
The CATECHOLAMINES are produced and metabolized in the ADRENAL MEDULLA.
The two most common catecholamines are:
1. EPINEPHRINE
2. NOREPINEPHRINE
These catecholamines are also called "EMERGENCY HORMONES" as they increase the ability of the body to respond to stressful situations.
They elevate blood pressure, increase glucose concentration in the blood stream and control a series of biochemical processes.
For more information about the topic visit the link below:
Become Healthy Now
Tuesday, April 1, 2008
Saturday, March 29, 2008
hCG -HUMAN CHORIONIC GONADOTROPIC HORMONE
hCG is the hormone being detected in most pregnancy tests. It is normally produced by the placenta during pregnancy and is also markedly elevated in pathologic conditions like seminoma, hydatidiform mole and teratoma, among others.
TOXICOLOGY

www.freeimages.co.uk
Divisions of Toxicology
1. Emergency - deals with overdosage of drugs
2. Drug Abuse Screening- deals with substances of abuse
3. Therapeutic Drug Monitoring - deals with drugs for therapeutic use
4. Forensic - deals with the medical -legal aspect
5. Industrial - deals with industrial products.
EMERGENCY TOXICOLOGY
SALICYLATE poisoning - is the most common cause of ET in children.
Salicylate/acetysalicylate - the active component of aspirin.
DRUG ABUSE SCREENING
Most common substances of abuse are cigarette and alcohol.
THERAPEUTIC DRUG MONITORING
The purpose of this is to establish the optimum concentration of the drug that could cure the patient.
FORENSIC
Prohibited drugs are usually involved in this.
INDUSTRIAL
pesticides and insecticides are the most common substances involved.
BLOOD GAS ANALYSIS OUTLINE
pCO2, pH and HCO3 are usually assayed. The results help in the evaluation whether a patient has acidosis or alkalosis.
Conditions:
Values : pH - decreased , PCO2 normal, HCO3 - decreased
Condition - metabolic acidosis
Compensatory mechanism - hyperventilation , increase excretion of CO2
decreased retention of CO2
Values: pH increased, HCO3 - increased , PCO2-normal
Condition - metabolic alkalosis
Compensatory mechanism - hypoventilation, decreased excretion of CO2
increased retention of CO2
Values : pH- increased , PCO2 - decreased , HCO3 -normal
Condition - respiratory alkalosis
Compensatory mechanism : increased retention of HCO3
decreased excretion of H+
Values: pH-decreased , PCO2 -increased, HCO3 -normal
Condition: respiratory acidosis
Compensatory mechanism : increased retention of HCO3,
increased excretion of H+
Henderson=Hasselbalch Equation: (H & H)
pH = 6.1 + log (HCO3)/DCO2
HCO = TCO2-DCO2
DCO2 = PCO2 X 0.031
Where: pH =indicates the acidity or alkalinity of a solution (hydrogen ion concentration.
HCO3 - bicarbonate
DCO2 - dissolved carbon dioxide
TCO2 - total carbon dioxide
Sample Problems:
Based on the following lab results obtained,
1. What is the acid base status of the patient?
2. What further test would you recommend?
3. What may be the possible causes of the condition?
4. Show all computations.
laboratory data:
TCO2 = 20 mmol/L
PCO2 = 30 mmHg
For more on blood gas analysis, visit the site below:
labtests on line
Friday, March 28, 2008
TURBIDIMETRY
Turbidimetry
ELECTROPHORESIS
Migration of charged particles or solutes in an electric field. The net charge of the molecule, their size and shape, the strength of the electric field and the support medium used, influence the rate and speed of distribution of the unknown particles.
'Electrophoresis' link';
Image from: http://en.wikipedia.org/?title=Gel_electrophoresis
EMISSION FLAME PHOTOMETRY (EFP)
• This method measures the concentration of an unknown solution by measuring the emitted flame from these solutions. Metal salts (Li,K,Na) are usually measured making use Of this method.
Image from this site, enter the LINK below for more information:
'Emission Flame Photometry! link';
Image from http://www.resonancepub.com/images/section701.gif
NEPHELOMETRY

Image from: http://www.lib.mcg.edu/.../ch4/ch4img/nephelom.jpg
and http://www.gmi-inc.com/CliniLab/Beckman%20Immage.htm
Enter the LINK below to know more:
'Nephelometry' link';
NEPHELOMETRY
The light that is scattered by particles in the unknown solution is measured and made as a basis of determining its concentration.
Factors affecting the amount of light scattered are:
a.the wavelength used – dispersion of light is inversely proportional to the
wavelength.
b.the size of the particles
c.the amount of particles in solution
d.the cross sectional area of the particles
e.the source of light - monochromatic lights give more reliable readings because they